FLUKE-1555
Fluke®* Actual product may vary from image
Insulation Tester, Voltage Rating: 250, 500, 1000, 2500, 5000, 10000 V, Amperage Rating: Induced: 2 MILAMP, Frequency Response: 50/60 HZ, Resistance Range: 200 KOHM - 2 TOHM, Accuracy: 5 - 20 PCT For 250, 500, 1000, 2500, 5000, 10000 V, 0, - 10 PCT At 1 MILAMP Load Current For Insulation Test, Plus/Minus (5 PCT Plus 2 NAMP)For Leakage Current, Plus/Minus (15 PCT RDG Plus 0.03 MFD)For Capacitance, Display: 75 MM Height X 105 MM Width LCD, Interface Type: PC Port, Enclosure: IP40, Dimensions: 269 MM Length X 277 MM Width X 160 MM Height, Environmental Conditions: Operating Temperature: -20 To 50 DEG C, Storage Temperature: -20 To 65 DEG C, Humidity 80 PCT, Altitude 2000 MR, CSA, CE Certified, EN 61326, IEC 61010-1: Overvoltage category II, Pollution Degree 2, IEC 61010-2-030: Measurement 600V CAT IV / 1000V CAT IIIIEC 61557-1, IEC 61557-2, C/UL Listed, For Capturing And Trending anomalies for troubleshooting, commissioning and preventative maintenance of insulation resistance
Details
MFG PART #:FLUKE-1555
TRC Part #:FLUKFLUKE1555
UPC #:095969550925
Inventory
$7,351.50 E
Details
MFG PART #:FLUKE-1555
TRC Part #:FLUKFLUKE1555
UPC #:095969550925
Inventory
Attributes
Features
Documentation
Attributes
Brand:Fluke®
Voltage Rating:250/500/1000/2500/5000/10000 VAC
Amperage Rating:2 mA
Frequency Response:50 to 60 Hz
Resistance Range:200 kOhm to 2 TOhm
Resistance:2 TOhm
Accuracy:5 to 20% for 250, 500, 1000, 2500, 5000, 10000 V, 0 to 10% at 1 mA Load Current for Insulation Test, +/- (5% + 2 uA) for Leakage Current, +/- (15% rdg + 0.03 uF) for Capacitance
Display Type:LCD
Safety Rating:CAT III 1000 V/CAT IV 600 V
Power Source:12 VDC Lead Acid Rechargeable Battery/Yuasa NP2.8-12
Interface:PC Port
Enclosure Type:IP40
Dimensions:269 mm L x 277 mm W x 160 mm H
Features
Test voltages to up 10 kV and save time by trending on the spot only with Fluke® Connect |
Warning function alerts the user that line voltage is present and gives the voltage reading up to 600 VAC/ VDC for increased user safety, selectable test voltages in 50 V steps from 250 - 1000 V, and 100 V steps above 1000 V |
Long battery life gives the user over 750 tests between charges |
Automatic calculation of dielectric absorption (DAR) and polarization index (PI) with no additional setup |
Ramp function for breakdown testing |
Timer settings up to 99 minutes for timed tests |
Guard system eliminates the effect of surface leakage current on high resistance measurements |
Measurements can be stored in up to 99 memory locations, with each location assigned a unique, user defined, label for easy recall |
75 x 105 mm LCD, Digital LCD/analog display |
2 deg pollution, -20 to 50 deg C temperature rating, IP rating IP40 |